ARCTON Basic XLP 250

Our ARCTON Basic compact industrial RO system is recommended for plants and factories requiring smaller volumes of permeate, but demanding a reliable and stable supply of purified water — up to 500 L/h.

3D Model

Reliable entry-level model in a compact design

The ARCTON Basic is designed for industrial partners seeking a stable, efficient reverse osmosis system with uncompromising quality, but with simplified functionality. It is ideal for smaller-scale industrial applications, boiler feed water or process pre-treatment, where compact size, low investment cost, and easy commissioning are key priorities.

The ARCTON Basic series is equipped with an XLP membrane, an integrated 2-in-1 RO unit, and two conductivity meters, enabling real-time monitoring of both feed water and permeate quality.

Key Features:

  • Integrated 2-in-1 RO + membrane housing design
  • Two conductivity meters
  • XLP membrane (low pressure)
  • Motorized ball valves
  • Industrial frame structure
  • Easy operation and quick maintenance
  • Low energy consumption

Parameters

Controller ROC-22100
Pump Nuert PRG10AS
Motor Soga M80 motor for booster pump
Membrane XLP11-4040A (Integrated RO membrane module)
Membrane housing
Filter housing FH-AQA1012
Filter cartridge FCPPS-10005
Frame Powder-coated carbon steel
Shut-off valves Motorized ball valves
Inlet connection G 1/2″
Permeate connection G 1/2″
Drain connection G 1/2″
Dimensions (H × W × D)
Permeate capacity 200 – 270 L/h
Permeate recovery rate 75%
Power supply 230 V / 50 Hz
Power consumption 0.75 kW
Operating pressure 10–14 bar
Maximum operating pressure 15 bar
Prefiltration rating 0.5 µm

Downloadable documents

Feed Water Requirements

The unit can only be operated safely and over the long term with drinking water quality feed water. The raw water parameters must comply with the applicable drinking water standards.

Maximum recommended values:

  • Water temperature: 5–40 °C
  • Chlorine: max. 0.1 mg/l
  • Hardness: max. 150 mg/l CaCO₃
  • Iron: max. 0.1 mg/l
  • Manganese: max. 0.05 mg/l
  • Silicate: max. 20 mg/l
  • COD: max. 4.0 mg/l
  • Hydrogen sulfide: not permitted
  • If these limits are exceeded, appropriate pre-treatment is required (e.g., softening, iron/manganese removal, filtration, chemical conditioning).

Recommended Applications:

Boiler feed water pre-treatment
Cooling circuits, closed-loop process systems
Food & beverage production, breweries
Livestock farms, dairy and poultry plants
Car washes – for spot-free rinsing
Industrial laundries and washing systems
Chemical and cosmetics manufacturing plants
Laboratories and research facilities
Greenhouses and precision irrigation systems
Request a quote, detailed technical documentation, or a consultation with our engineers – or select the appropriate model in our product selector, where you’ll find all necessary specifications and downloadable documents.

Euro-Clear - Arcton

Személyre szabott árajánlat

Euro-Clear - Arcton

Request a Personalized Quote

SUMMER SHUTDOWN

Our office is closed:

August 5, 2024 – August 9, 2024

Last order day:
July 29, 2024

Last parcel delivery day:
31 July 2024

Last day of delivery:
August 2, 2024 / – 3:00 p.m